815 kVP表kVp Meter

放大字体  缩小字体 发布日期:2011-06-27  浏览次数:535
815 kVP表kVp Meter and Exposure Time Meter


The ECC kVp meter and exposure timer Measures the peak x-ray accelerating voltage from tungsten x-ray generators. To measure peak kV the user simply places the instrument in the beam and takes an x-ray. In addition to measuring kVp, the unit also measures the exposure time and displays the x-ray waveform type. The Capintec kVp Meter can be used on radiographic, fluoroscopic and dental x-rays. There is a high resolution mode which is used for measurements on older x-rays and x-rays with slow rise times. The kVp Meter has a large display which is readable from outside the x-ray room.


Features
Small Hand Held Size
Easy to use
Non invasive
High Accuracy
Battery Operated
Two Year Warranty
Measures kVp and exposure time
simultaneously
Compact size
Durable ABS Plastic Case
Custom Carrying Case Option

Specifications
Range
45 to 125 kV
kVp Accuracy
2% +/- 1 kV, at 25 to 100 mA
18 to 42 cm from head, for
Tungsten target x-ray tube with 1.5
mm Al equivalent filtration
Exposure Time Accuracy
2% +/- 3 millisecond
Minimum exposure time is 100
millisecond
Minimum Exposure Time (kVp
Measurement)
100 millisec - High Speed Mode
(normal)
200 millisec - High Resolution Mode
Minimum Current (mA)
7 mA at 50 kV, 10 cm from x-ray
source
Also depends on focus / collimation
Display
0.4"(10.2mm) Liquid Crystal
8 Character Alphanumeric


Power

4 AA Batteries accessible from bottom
of case
Low Battery Indicator
Battery Life
48 hours continuous
Typically 9 months of normal use
Controls/Indicators
ON/OFF Switch
Illuminated push-button with green
power-on indication
Mode Switch
Momentary push-button
8 Character Liquid Crystal Display
Oscilloscope output
Physical Size
150 x 120 x 58.5 mm
5.9 x 4.7 x 2.3 inches
Weight
0.7 kG (1.5 lb)
Connections
None required for normal kVp
measurement
3.5mm Jack for Oscilloscope Output
Optional Accessories
Padded Cordura Carrying Case
Oscilloscope Interface Cable


Typical Applications
Measurement of Exposure
Verification of peak x-ray voltage
Constancy checks
X-ray calibration
Quality Assurance
Measurement of X-ray Exposure Time
Half Value Layer determination
Troubleshooting and Repair of X-rays



Contact We:

Huaruison Science and Technology Development Co., Ltd.
Address:No.16 guanghuaRoad,Tongzhou Development Zone Beijing 10100,P.R.China
Phone:0086-10-51266093,QQ:1275041125
Fax:0086-10-51266093
E-mail:huaruison@yahoo.com.hk
http://www.huaruison.com
http://www.eccxray.com/zhongkao.html
http://www.xraytest.cn


特别提示:本信息由相关企业自行提供,真实性未证实,仅供参考。请谨慎采用,风险自负。


[ 商情搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]


 
相关商情
推荐商情
点击排行